40 / 140 page ![]() TLE9461ES Lite CAN SBC Family System Features Datasheet 40 Rev.1.1 2019-09-27 5.4 High-Voltage Measurement Interface 5.4.1 Block Description This function provides the possibility to measure a voltage, e.g. the unbuffered battery voltage, with the protected WK/VSENSE HV-input. The measured voltage is routed out at FO/GPIO in case it is not configured as FO. A simple external voltage divider needs to be placed to provide the appropriate voltage level to the microcontroller A/D converter input. For power-saving reasons, the function is available only in SBC Normal Mode and it is disabled in all other SBC modes. The benefit of the function is that the signal is measured by a HV-input pin and that there is no current flowing through the resistor divider during low-power modes. The functionality is shown in a simplified application diagram in Figure 46. 5.4.2 Functional Description This measurement function is by default disabled. In this case, WK/VSENSE and FO/GPIO have their default functionality. The switch S_MEAS is open for this configuration (see Figure 46), i.e. there is no connection between the pins. The measurement function can be enabled via the SPI bit WK_MEAS. If WK_MEAS is set to ‘1’, then the measurement function is enabled and the switch S_MEAS is closed in SBC Normal Mode. S_MEAS is open in all other SBC modes. In this function the pull-up and pull-down currents of WK/VSENSE and FO/GPIO are disabled and the internal WK/VSENSE and FO/GPIO signals are gated. In addition, the settings for WK/VSENSE and FO/GPIO in the registers WK_PUPD_CTRL, WK_CTRL_1 and GPIO_CTRL are ignored but changing these setting is not prevented. The registers WK_STAT_0, WK_STAT_1 and WK_LVL_STAT are not updated with respect to the inputs WK/VSENSE and FO/GPIO. However, if only WK/VSENSE or GPIO WK are set as wake sources and a SBC Sleep Mode command is set, then the SPI_FAIL flag is set and the SBC changes into SBC Restart Mode (see Chapter 5.1 also for wake capability of WK/VSENSE and GPIO WK). If WK_MEAS is set then neither the FO (including the FO test via FO_ON) nor the GPIO functionality or wake functionality is available. Trying to change the GPIO_CTRL configurations will set the SPI_FAIL. If FO/GPIO is configured as FO or any other GPIO configuration, then WK_MEAS cannot be set and SPI_FAIL is triggered, i.e. FO/GPIO must be first set Off initially. Table 11 Differences between Normal WK Function and Measurement Function Affected Settings/Modules for WK/VSENSE and FO/GPIO Inputs WK_MEAS = 0 WK_MEAS = 1 S_MEAS configuration ‘open’ ‘closed’ in SBC Normal Mode, ‘open’ in all other SBC Modes but configuration is kept Internal WK/VSENSE & FO/GPIO signal processing Default wake and level signaling function, WK_STAT_0, WK_STAT_1 and WK_LVL_STAT are updated accordingly WK/VSENSE and FO/GPIO signals are gated internally, WK_STAT_0, WK_STAT_1 and WK_LVL_STAT are not updated |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |