Back Button SH7713 Datasheet HTML 155Page - Renesas Technology Corp SH7713 Datasheet HTML 156Page - Renesas Technology Corp SH7713 Datasheet HTML 157Page - Renesas Technology Corp SH7713 Datasheet HTML 158Page - Renesas Technology Corp SH7713 Datasheet HTML 159Page - Renesas Technology Corp SH7713 Datasheet HTML 160Page - Renesas Technology Corp SH7713 Datasheet HTML 161Page - Renesas Technology Corp SH7713 Datasheet HTML 162Page - Renesas Technology Corp SH7713 Datasheet HTML 163Page - Renesas Technology Corp Next Button
Zoom Inzoom in Zoom Outzoom out
 159 / 904 page
background image
Section 3 DSP Operating Unit
Rev.1.50 Aug. 30, 2006 Page 119 of 860
REJ09B0288-0150
Table 3.21
Variation of ALU Fixed-Point Operations
Mnemonic
Function
Source 1
Source 2
Destination
PADD
Addition
Sx
Sy
Dz (Du)
PSUB
Subtraction
Sx
Sy
Dz (Du)
PADDC
Addition with carry
Sx
Sy
Dz
PSUBC
Subtraction with borrow
Sx
Sy
Dz
PCMP
Comparison
Sx
Sy
—
Sx
All 0
Dz
PCOPY
Data copy
All 0
Sy
Dz
Sx
All 0
Dz
PABS
Absolute
All 0
Sy
Dz
Sx
All 0
Dz
PNEG
Negation
All 0
Sy
Dz
PCLR
Clear
All 0
All 0
Dz
Table 3.22
Correspondence between Operands and Registers
Register
Sx
Sy
Dz
Du
A0
Yes
Yes
Yes
A1
Yes
Yes
Yes
M0
Yes
Yes
M1
Yes
Yes
X0
Yes
Yes
Yes
X1
Yes
Yes
Y0
Yes
Yes
Yes
Y1
Yes
Yes
As shown in figure 3.10, data loaded from the memory at the MA stage, which is programmed at
the same line as the ALU operation, is not used as a source operand for this operation, even
though the destination operand of the data load operation is identical to the source operand of the
ALU operation. In this case, previous operation results are used as the source operands for the
ALU operation, and then updated as the destination operand of the data load operation.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com