| Electronic Components Datasheet Search |
|
UCS1002-3 Datasheet(PDF) 37 Page - Microchip Technology |
|
|
|||||||||||||||||||||||||||||
UCS1002-3 Datasheet(HTML) 37 Page - Microchip Technology |
|
37 / 114 page ![]() 2023 Microchip Technology Inc. and its subsidiaries DS20006852A-page 37 UCS1002-3 If the RATION_EN control is set to ‘0’ prior to reaching the charge rationing threshold, rationing is disabled and the Total Accumulated Charge registers are cleared. If the RATION_EN control is set to ‘0’ after the charge rationing threshold is reached, the following are done: 1. RATION status bit is cleared. 2. The ALERT# pin is released if asserted by the rationing circuitry and no other conditions are present. 3. The M1, M2, EM_EN, S0 and PWR_EN controls are checked to determine the power state. See Note 1 in Table 7-3. Setting the RATION_RST control to ‘1’ automatically resets the Total Accumulated Charge registers to 00_00h. If this is done prior to reaching the charge rationing threshold, the data continues to be accumulated restarting from 00_00h. If this is done after the charge rationing threshold is reached, the UCS1002-3 takes action as shown in Table 7-2. Report Ignore Release ALERT# pin. Report and Disconnect Open port power switch. See the Report and Disconnect (default) entry in Table 7-1. Disconnect and Go to Sleep 1. Release the ALERT# pin. 2. Remove charger emulation profile. 3. Open the port power switch. 4. Enter the Sleep state. See the Disconnect and Go to Sleep entry in Table 7-1. Report and Disconnect Ignore 1. Release the ALERT# pin. 2. Check the M1, M2, EM_EN, S0, and PWR_EN controls and enter the indicated power state if the controls changed (see Note 1). Report Check the M1, M2, EM_EN, S0, and PWR_EN controls and enter the indicated power state if the controls changed (see Note 1). Disconnect and Go to Sleep 1. Release the ALERT# pin. 2. Enter the Sleep state. See the Disconnect and Go to Sleep entry in Table 7-1. Disconnect and Go to Sleep Ignore Check the M1, M2, EM_EN, S0, and PWR_EN controls and enter the indicated power state if the controls changed (see Note 1). Report 1. Assert the ALERT# pin. 2. Check the M1, M2, EM_EN, S0, and PWR_EN controls and enter the indicated power state if the controls changed (see Note 1). Report and Disconnect 1. Assert the ALERT# pin. 2. Check the M1, M2, EM_EN, S0, and PWR_EN controls to determine the power state, then enter that state except that the port power switch and bypass switch are not closed (see Note 1). TABLE 7-3: EFFECTS OF CHANGING RATIONING BEHAVIOR AFTER THRESHOLD REACHED Previous Behavior New Behavior Actions taken Note 1: Any time the charge rationing circuitry checks the pin conditions when changing rationing behavior or resetting charge rationing, if the external pin conditions have changed, then charger emulation is restarted (provided emulation is enabled via the pin states). If the pin conditions did not change, the UCS1002-3 returns to the previous power state as if the rationing threshold is not reached (for example, it does not discharge VBUS or restart emulation). Note: If the rationing behavior is set to “Report and Disconnect” when the charge rationing threshold is reached, and then the RATION_EN bit is cleared, the portable device may start charging sub-optimally because the charger emulation profile is removed. Toggle the PWR_EN control to restart charger emulation. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |