| Electronic Components Datasheet Search |
|
UCS1002-3 Datasheet(PDF) 52 Page - Microchip Technology |
|
|
|||||||||||||||||||||||||||||
UCS1002-3 Datasheet(HTML) 52 Page - Microchip Technology |
|
52 / 114 page ![]() UCS1002-3 DS20006852A-page 52 2023 Microchip Technology Inc. and its subsidiaries bit 0 OVER_LIM: Indicates that the IBUS current has exceeded both the ILIM threshold and the IBUS_R2MIN threshold settings. This bit is cleared when read if the error condition is removed or if the ERR bit is cleared. This bit causes the ALERT# pin to be asserted and the device to enter the Error state. 1 = IBUS > ILIM and IBUS_R2MIN 0 = IBUS did not exceed both ILIM threshold and the IBUS_R2MIN threshold settings Note 1: If the Auto-Recovery Fault Handling is not used, the ERR bit must be written to a logic '0' to be cleared. It is also cleared when the PWR_EN control is disabled. 2: Note that the ERR bit does not necessarily reflect the ALERT# pin status. The ALERT# pin may be cleared or asserted without the ERR bit changing states. REGISTER 10-4: GENERAL STATUS REGISTER (ADDRESS 11h) R-0 U-x U-x R-0 R-0 R-C R-C R-C RATION — — CC_MODE TREG LOW_CUR REM ATT bit 7 bit 0 Legend: R = Readable bit W = Writable bit U = Unimplemented bit -n = Value at POR ‘1’ = Bit is set ‘0’ = Bit is cleared x = Bit is unknown C = Clear on Read bit 7 RATION: Indicates that the UCS1002-3 has delivered the programmed amount of power to a portable device. If the RATION_BEH bits are set to interrupt the host, this bit causes the ALERT# pin to be asserted. This bit is cleared when read. This bit is also automatically cleared when the RTN_RST bit is set or the RTN_EN bit is cleared (see Section 10.4.1 “General Configuration Register”). 1 = UCS1002-3 delivered the programmed amount of power to a portable device 0 = UCS1002-3 did not deliver the programmed amount of power to a portable device bit 6-5 Unimplemented bit 4 CC_MODE: Indicates that the IBUS current has exceeded ILIM. Current is in Region 2 (IBUS_R2MIN). 1 = IBUS > ILIM 0 = IBUS < ILIM bit 3 TREG: Indicates that the internal temperature has exceeded TREG and that the current limit is reduced. This bit is cleared when read and does not cause the ALERT# pin to be asserted, unless the ALERT_LINK bit is set. 1 = Internal temperature > TREG 0 = Internal temperature < TREG bit 2 LOW_CUR: Indicates that a portable device has reduced its charge current to below ~6.4 mA and may be finished charging. This bit is cleared when read and does not cause the ALERT# pin to be asserted, unless the ALERT_LINK bit is set. 1 = IBUS < 6.4 mA 0 = IBUS > 6.4 mA bit 1 REM: Indicates that a Removal Detection event has occurred and there is no longer a portable device present. This bit is cleared when read and does not cause the ALERT# pin to be asserted. It causes the A_DET# pin to be released. 1 = Removal Detected 0 = No Removal Detected bit 0 ATT: Indicates that an Attach Detection event has occurred and there is a new portable device present. This bit is cleared when read and does not cause the ALERT# pin to be asserted. It causes the A_DET# pin to be asserted. 1 = Attach Detected 0 = No Attach Detected REGISTER 10-3: INTERRUPT STATUS REGISTER (ADDRESS 10h) (CONTINUED) |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |