L99PM60J Datasheet(HTML) 22 Page - STMicroelectronics |
|
22 / 75 page ![]() Detailed description L99PM60J 22/75 Doc ID 18309 Rev 6 2.8 Reset output (NRESET) If V1 is turned on and the voltage exceeds the V1 reset threshold, the reset output “NRESET” is pulled up by internal pull up resistor to V1 voltage after a reset delay time tReset. This is necessary for a defined start of the micro controller when the application is switched on. Since the NRESET output is realized as an open drain output it is also possible to connect an external NRESET open drain NRESET source to the output. It must be considered that as soon the NRESET is released from the L99PM60J the watchdog timing starts. A reset pulse tReset is generated in case of: ● V1 drops below Vrth (configurable by SPI) for more than V1UFT ● Watchdog failure 2.9 LIN bus interface General features: ● Speed communication up to 20kbit/s. ● LIN 2.1 compliant (SAE J2602 compatible) transceiver. ● Function range from +40V to -18V DC at LIN Pin. ● GND disconnection fail safe at module level. ● Off mode: does not disturb network. ● GND shift operation at system level. ● Micro controller Interface with CMOS compatible I/O pins. ● ESD and transient immunity according to ISO7637 and EN / IEC61000-4-2 ● Matched output slopes and propagation delay In order to further reduce the current consumption in standby mode, the integrated LIN bus interface offers an ultra low current consumption. 2.9.1 Error handling The L99PM60J provides the following 3 error handling features which are not described in the LIN Spec. Revision 2.1, but are realized in different stand alone LIN transceivers / micro controllers to switch the application back to normal operation mode. At Vs > Vpor (i.e. Vs power-on reset threshold), the LIN transceiver is enabled. The LIN transmitter is disabled in case of the following errors: ● Dominant TxDL time out ● LIN permanent recessive ● Thermal shutdown 1 ● VS overvoltage / VS undervoltage The LIN receiver is not disabled in case of any failure condition. Dominant TxD time out If TXD is in dominant state (low) for more than tdom(TXDL)(typ) the transmitter is disabled. The status bit is latched and can be read and optionally cleared by SPI. The transmitter remains disabled until the status register is cleared. This feature can be disabled via SPI. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |