| Electronic Components Datasheet Search |
|
AN3985 Datasheet(PDF) 82 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
AN3985 Datasheet(HTML) 82 Page - STMicroelectronics |
|
82 / 105 page ![]() M24LRxx layer AN3985 82/105 Doc ID 022255 Rev 2 M24LRxx_Write_EH_Cfg function This function sends, through the CR95HF, Write_EH_Cfg command to a contactless tag in the field. On receiving the write Energy Harvesting Configuration command, the M24LRxxE-R contactless tag writes the data provided to the configuration byte and reports the status of the command. M24LRxx_Write_DO_Cfg function This function sends, through the CR95HF, Write_DO_Cfg command to a contactless tag in the field. On receiving the Write_DO_Cfg command the M24LRxxE-R contactless tag writes the data provided to the configuration byte and reports the status of the command. Table 140. M24LRxx_Write_EH_Cfg function description Prototype u8 Write_EH_Cfg(ISO15693_Tag* MyTag, const u8 Request_flags,const u8* Tag_UID, u8 Configuration_Byte); Input parameter Request_flags: Specifies the actions to be performed by the contactless tag and whether corresponding fields are present or not. (1) Tag_UID: pointer on the UID (optional) Configuration_Byte: the byte to write to the configuration byte (2) 1. The Address flag indicates if Tag_UID field will be added to the command (addressed mode). 2. Only bits 0 to 2 are written, bit 3 is ignored. Output parameter MyTag: pointer on the structure that contains the tag response Return parameter M24LRxx_ERROR_CODE: The command failed. M24LRxx_ERROR_PARAMETERS_REQUEST_FLAGS: The inventory flag is set. M24LRxx_SUCCESS_CODE: The tag answered the command. Caution: M24LRxx_Write_DO_Cfg function description Prototype u8 M24LRxx_Write_DO_Cfg (ISO15693_Tag* MyTag, const u8 Request_flags,const u8* Tag_UID, u8 Configuration_Byte); Input parameter Request_flags: Specifies the actions to be performed by the contactless tag and whether corresponding fields are present or not. (1) Tag_UID: pointer on the UID (optional) Configuration_Byte: the byte to write to the configuration byte (2) 1. The Address flag indicates if Tag_UID field will be added to the command (addressed mode). 2. Only bits 0 to 2 are written, bit 3 is ignored. Output parameter MyTag: pointer on the structure that contains the tag response Return parameter M24LRxx_ERROR_CODE: The command failed. M24LRxx_ERROR_PARAMETERS_REQUEST_FLAGS: The inventory flag is set. M24LRxx_SUCCESS_CODE: The tag answered the command. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |