| Electronic Components Datasheet Search |
|
ADF5902 Datasheet(PDF) 35 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADF5902 Datasheet(HTML) 35 Page - Analog Devices |
|
35 / 39 page ![]() Data Sheet ADF5902 Rev. 0 | Page 35 of 39 Frequency Deviation The frequency deviation for each frequency hop is set by fDEV = (fPFD/225) × (DEV × 2DEV_OFFSET) (7) where: fPFD is the PFD frequency. DEV is a 16-bit word (Bits[DB20:DB5] in Register R14). DEV_OFFSET is a 4-bit word (Bits[DB24:DB21] in Register R14). Time per step The time between each frequency hop is set by Timer = CLK1 × CLK2 × (1/fPFD) (8) where: CLK1 and CLK2 are the 12-bit clock values (12-bit CLK1 divider in Register R7 and 12-bit CLK2 divider in Register R13). Bits[DB20:DB19] in Register R13 must be set to 11 for ramp divider. fPFD is the PFD frequency. Either CLK1 or CLK2 must be greater than 1, that is, CLK1 = CLK2 = 1 is not allowed. Number of Steps A 20-bit step value (Bits[DB24:DB5] in Register R15) defines the number of frequency hops that take place. The INT value cannot be incremented by more than 28 = 256 from its starting value. RAMP AND MODULATION All ramps are generated according to the scheme shown in Figure 49. The total ramp is separated into four sections. Each section consists of a delay section and a slope section. Each slope is made up of one or more steps. Each step has a programmed frequency deviation and step time. There are numerous ramp shapes available (see the Waveform Generation section). Depending on the chosen shape, some or all of the ramp slopes must be programmed. Figure 49 shows what must be programmed for each shape. The slope being programmed is controlled by CLK DIV SEL (Register R13, Bits[DB6:DB5]). DEV SEL (Register R14, Bits[DB26:DB25]). Step SEL (Register R15, Bits[DB26:DB25]). Typically, each register must be written multiple times, one time for each slope. The frequency deviation for each step of a slope is set by fDEV = (fPFD/225) × (DEV × 2DEV_OFFSET) where: fDEV is the frequency deviation of a step. fPFD is the PFD frequency. DEV is the deviation value (Register R14, Bits[DB20:DB5]). DEV_OFFSET is the deviation offset (Register R14, Bits[DB24:DB21]). The time for each step of a slope is set by Timer = CLK1 × CLK2 × (1/fPFD) where: Timer is the time per step. CLK1 is the CLK1 value (Register R7, Bits[23:12]). CLK2 is the CLK2 value (Register R13, Bits[18:7]). CLK1 is common to all slopes. The number of steps per slope is programmed in Register R15, Bits[DB24:DB5]. When programming the registers for a ramp, write the registers in descending order. Then write to Register R5 to enable the ramp (Register R5, Bit DB29 = 1) must be last. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |