| Electronic Components Datasheet Search |
|
ADF5902 Datasheet(PDF) 3 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADF5902 Datasheet(HTML) 3 Page - Analog Devices |
|
3 / 39 page ![]() Data Sheet ADF5902 Rev. 0 | Page 3 of 39 SPECIFICATIONS AHI = TX_AHI = RF_AHI = VCO_AHI = DVDD = CP_AHI = 3.3 V ± 5%, GND = 0 V, dBm referred to 50 Ω, TA = TMAX to TMIN, unless otherwise noted. The operating temperature range is −40°C to +105°C. Table 1. Parameter Min Typ Max Unit Test Conditions/Comments OPERATING CONDITIONS RF Frequency Range 24 24.25 GHz VCO CHARACTERISTICS VTUNE 0.5 2.5 V VTUNE Impedance 100 kΩ VCO Phase Noise Performance Closed-loop, 10 kHz loop filter At 100 kHz Offset −88 dBc/Hz At 1 MHz Offset −108 dBc/Hz At 10 MHz Offset −128 dBc/Hz Amplitude Noise −150 dBc/Hz At 1 MHz offset Static Pulling VCO Frequency (fVCO) Change vs. Load ±2 MHz Open-loop into 2:1 voltage standing wave ratio (VSWR) load Dynamic Pulling Transmitter On or Off Switch Change ±10 MHz Open-loop Dynamic Pulling Transmitter to Transmitter Switch Change ±5 MHz Open-loop Pushing fVCO Change vs. AHI Change ±5 MHz/V Open-loop Spurious Level Harmonics −30 dBc Spurious Level Nonharmonics <−70 dBc POWER SUPPLIES AHI, TX_AHI, RF_AHI, VCO_AHI, DVDD, CP_AHI 3.135 3.3 3.465 V Total Current (ITOTAL)1 190 mA Software Power-Down Mode 1.2 mA Hardware Power-Down Mode 200 μA TRANSMITTER OUTPUT Output Power 2 8 12 dBm Output Impedance 50 Ω On to Off Isolation 30 dB Single transmitter output switched on to off Transmitter to Transmitter Isolation 25 dB Power-Up/Power-Down Time 200 ns LO OUTPUT Output Power −7 −1 +5 dBm Output Impedance 50 Ω On to Off Isolation 35 dB PHASE FREQUENCY DETECTOR (PFD) Phase Detector Frequency2 110 MHz CHARGE PUMP Charge Pump Current (ICP) Sink and Source Current Programmable High Value 4.48 mA RSET = 5.1 kΩ; RSET is a resistor to ground that sets the maximum charge pump output current Low Value 280 μA Absolute Accuracy 2.5 % RSET = 5.1 kΩ RSET Range 5.049 5.1 5.151 kΩ ICP Tristate Leakage Current 1 nA Sink and source current Sink and Source Matching 2 % 0.5 V < charge pump voltage (VCP) < CP_AHI − 0.6 V ICP vs. VCP 2 % 0.5 V < VCP < CP_AHI − 0.6 V ICP vs. Temperature 2 % VCP = CP_AHI/2 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |