| Electronic Components Datasheet Search |
|
GRM552B11H102KA01D Datasheet(PDF) 60 Page - Murata Manufacturing Co., Ltd. |
|
|
|||||||||||||||||||||||||||||
GRM552B11H102KA01D Datasheet(HTML) 60 Page - Murata Manufacturing Co., Ltd. |
|
60 / 221 page ![]() Continued from the preceding page. Continued on the following page. Solder the capacitor on the test jig (glass epoxy board) in the same manner and under the same conditions as (10). The capacitor should be subjected to a simple harmonic motion having a total amplitude of 1.5mm, the frequency being varied uniformly between the approximate limits of 10 and 55Hz. The frequency range, from 10 to 55Hz and return to 10Hz, should be traversed in approximately 1 minute. This motion should be applied for a period of 2 hours in each of 3 mutually perpendicular directions (total of 6 hours). 11 Vibration Appearance No defects or abnormalities Capacitance Within the specified tolerance D.F. B1, B3, R1, *R6, *R7, C7, C8, E7, D7: 0.1 max. C6: 0.125 max. D8: 0.15 max. F1, F5: 0.2 max. *GRM31CR71E106: 0.125 max. GRM31CR6 0J/0G 107: 0.15 max. Solder the capacitor on the test jig (glass epoxy board) shown in Fig. 1a using a eutectic solder. Then apply 10N* force in parallel with the test jig for 10 ±1sec. The soldering should be done either with an iron or using the reflow method and should be conducted with care so that the soldering is uniform and free of defects such as heat shock. *1N: GRM02, 2N: GRM03, 5N: GRM15/GRM18 10 Adhesive Strength of Termination No removal of the terminations or other defects should occur. Fig. 1a GRM Series Specifications and Test Methods (2) (Note 1)-Typical Inspection a Type 0.2 0.3 0.4 1.0 1.2 2.2 2.2 3.5 4.5 b 0.56 0.9 1.5 3.0 4.0 5.0 5.0 7.0 8.0 c 0.23 0.3 0.5 1.2 1.65 2.0 2.9 3.7 5.6 GRM02 GRM03 GRM15 GRM18 GRM21 GRM31 GRM32 GRM43 GRM55 c Baked electrode or copper foil Solder resist The capacitance change should be measured after 5 min. at each specified temp. stage. The ranges of capacitance change compared with the reference temperature value over the temperature ranges shown in the table should be within the specified ranges.* In case of applying voltage, the capacitance change should be measured after 1 more min. with applying voltage in equilibration of each temp. stage. *GRM32DR60J226, GRM43 B1/B3/R6 0J/1A 336/476: 1.0 ±0.2Vrms GRM155B30G475, GRM155B30J 225, GRM21BB30J476, GRM155R60E106, GRM188 B3/R6 0E/0G/0J 226: 0.2 ±0.05Vrms •Initial measurement for high dielectric constant type Perform a heat treatment at 150 +0/–10 °C for one hour and then set for 24 ±2 hours at room temperature. Perform the initial measurement. 9 Capacitance Temperature Characteristics No bias B1, B3 : Within ±10% (–25 to +85°C) F1 : Within +30/–80% (–25 to +85 °C) R6 : Within ±15% (–55 to +85°C) R1, R7 : Within ±15% (–55 to +125°C) F5 : Within +22/–82% (–30 to +85 °C) C6 : Within ±22% (–55 to +85°C) C7 : Within ±22% (–55 to +125°C) C8 : Within ±22% (–55 to +105°C) D7 : Within +22/–33% (–55 to +125 °C) E7 : Within +22/–56% (–55 to +125 °C) D8 : Within +22/–33% (–55 to +105 °C) 50% of the Rated Voltage B1: Within +10/–30% R1: Within +15/–40% F1: Within +30/–95% Temperature ( °C) Step 25 ±2 (for R6, R7, C6, C7, C8, D7, D8, E7, F5) 20 ±2 (for B1, B3, F1, R1) –55 ±3 (for R1, R6, R7, C6, C7, C8, D7, D8, E7) –30 ±3 (for F5) –25 ±3 (for B1, B3, F1) 25 ±2 (for R6, R7, C6, C7, C8, D7, D8, E7, F5) 20 ±2 (for B1, B3, F1, R1) 125 ±3 (for R1, R7, C7, D7, E7) 105 ±3 (for C8, D8) 85 ±3 (for B1, B3, F1, F5, R6, C6) 20 ±2 (for B1, F1, R1) –55 ±3 (for R1) –25 ±3 (for B1, F1) 20 ±2 (for B1, F1, R1) 125 ±3 (for R1) 85 ±3 (for B1, F1) Applying Voltage (V) No bias 50% of the rated voltage 1 2 3 4 5 6 7 8 No. Test Method Specifications Item GRM Series Specifications and Test Methods (2) (Note 1)-Typical Inspection 58 !Note • Please read rating and !CAUTION (for storage, operating, rating, soldering, mounting and handling) in this catalog to prevent smoking and/or burning, etc. • This catalog has only typical specifications because there is no space for detailed specifications. Therefore, please approve our product specifications or transact the approval sheet for product specifications before ordering. (Note 1) These Specifications and Test Methods indicate typical inspection. Please refer to individual specifications (our product specifications or the approval sheet). When no "*" is added in PNs table, please refer to GRM Series Specifications and Test Methods (1). When "*" is added in PNs table, please refer to GRM Series Specifications and Test Methods (2). • This PDF catalog is downloaded from the website of Murata Manufacturing co., ltd. Therefore, it’s specifications are subject to change or our products in it may be discontinued without advance notice. Please check with our sales representatives or product engineers before ordering. • This PDF catalog has only typical specifications because there is no space for detailed specifications. Therefore, please approve our product specifications or transact the approval sheet for product specifications before ordering. !Note C02E.pdf 10.12.20 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |