| Electronic Components Datasheet Search |
|
GRM552B11H102KA01D Datasheet(PDF) 62 Page - Murata Manufacturing Co., Ltd. |
|
|
|||||||||||||||||||||||||||||
GRM552B11H102KA01D Datasheet(HTML) 62 Page - Murata Manufacturing Co., Ltd. |
|
62 / 221 page ![]() Continued from the preceding page. Apply 150%* of the rated voltage for 1000 ±12 hours at the maximum operating temperature ±3°C. Let sit for 24±2 hours at room temperature, then measure. The charge/discharge current is less than 50mA. * Part Numbers with # have individual specification. As for these Part Numbers, please refer to table A. •Initial measurement Perform a heat treatment at 150+0/–10 °C for one hour and then let sit for 24 ±2 hours at room temperature. Perform the initial measurement. •Measurement after test Perform a heat treatment at 150+0/–10 °C for one hour and then let sit for 24 ±2 hours at room temperature, then measure. 17 Durability Appearance No defects or abnormalities I.R. More than 25 Ω · F D.F. B1, B3, R1, R6, R7, C6, C7, *C8, E7, D7, D8: 0.2 max. F1, F5: 0.4 max. *GRM319C81A106, GRM31MC81A106: 0.125 max. Capacitance Change B1, B3, R1, *R6, R7, C6, C7, *C8, E7, D7, D8: Within ±12.5% F1, F5: Within ±30% *GRM188C8 0E/0G 106, GRM219R60G226: within ±15% Apply the rated voltage at 40 ±2°C and 90 to 95% humidity for 500 ±12 hours. The charge/discharge current is less than 50mA. •Initial measurement Perform a heat treatment at 150+0/–10 °C for one hour and then let sit for 24 ±2 hours at room temperature. Perform the initial measurement. •Measurement after test Perform a heat treatment at 150+0/–10 °C for one hour and then let sit for 24 ±2 hours at room temperature, then measure. 16 High Temperature High Humidity (Steady) Appearance No defects or abnormalities I.R. More than 12.5 Ω · F D.F. B1, B3, R1, R6, R7, C6, C7, *C8, E7, D7, D8: 0.2 max. F1, F5: 0.4 max. *GRM319C81A106, GRM31MC81A106: 0.125 max. Capacitance Change B1, B3, R1, R6, R7, C6, C7, C8, E7, D7, D8: Within ±12.5% F1, F5: Within ±30% No. Test Method Specifications Item GRM Series Specifications and Test Methods (2) (Note 1)-Typical Inspection Part Number Dimension L ZW (mm) 1.0 Z0.5 1.0 Z0.5 1.6 Z0.8 2.0 Z1.25 3.2 Z1.6 3.2 Z1.6 GRM155C80J684KE15D GRM155C80J684ME15D GRM188C80G106ME47D GRM21BC80J226ME51L GRM319D71C475KA12D GRM319D71C475MA12D Temp. Char. X6S X6S X6S X6S X7T X7T 6.3 6.3 4 6.3 16 16 Capacitance (F) 0.68 µ 0.68 µ 10 µ 22 µ 4.7 µ 4.7 µ Cap. Tol (%) ±10% ±20% ±20% ±20% ±10% ±20% Spec. Test Methods (2) (2) (2) (2) (2) (2) Applied Testing Voltage at Durability Rated Volt. Z100% Rated Volt. Z100% Rated Volt. Z100% Rated Volt. Z100% Rated Volt. Z100% Rated Volt. Z100% Part Numbers of table A are designed for use in the circuits where continuous applied voltage to the capacitor is derated than rated voltage. These Part Numbers guarantee Durability Test with 100% x rated voltage as testing voltage at the maximum operating temperature. The following voltage and temperature derating conditions are recommended for use to ensure the same reliability level as normal specification. • Recommended Derating Conditions on Voltage and Temperature Table A 0 20 0 40 60 80 100 120 25 50 75 100 Temperature at Product ( °C) 125 150 Product for 125 °C Product for 105 °C Product for 85 °C Rated Volt. (Vdc) GRM Series Specifications and Test Methods (2) (Note 1)-Typical Inspection 60 !Note • Please read rating and !CAUTION (for storage, operating, rating, soldering, mounting and handling) in this catalog to prevent smoking and/or burning, etc. • This catalog has only typical specifications because there is no space for detailed specifications. Therefore, please approve our product specifications or transact the approval sheet for product specifications before ordering. (Note 1) These Specifications and Test Methods indicate typical inspection. Please refer to individual specifications (our product specifications or the approval sheet). When no "*" is added in PNs table, please refer to GRM Series Specifications and Test Methods (1). When "*" is added in PNs table, please refer to GRM Series Specifications and Test Methods (2). • This PDF catalog is downloaded from the website of Murata Manufacturing co., ltd. Therefore, it’s specifications are subject to change or our products in it may be discontinued without advance notice. Please check with our sales representatives or product engineers before ordering. • This PDF catalog has only typical specifications because there is no space for detailed specifications. Therefore, please approve our product specifications or transact the approval sheet for product specifications before ordering. !Note C02E.pdf 10.12.20 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |