74 / 250 page ![]() Errors 74 Intel® 6400/6402 Advanced Memory Buffer Datasheet 6.1.4 Other Errors 6.2 Error Logging 6.2.1 Error Logging Procedure There are three basic types of errors in FBD: OverTemp, Alerts and Status Only Errors.The first occurrence of any type of unmasked error are flagged in the FERR register. Multiple bits can be set in this register if multiple errors occur in the same clock period. Subsequent errors are flagged in the NERR register. Unmasked “Alert” errors generate in-band link alert messages. All unmasked errors also set the error bit in FBDS0 that is returned in regularly scheduled in-band status response messages that occur following Sync commands. There are error data logs associated with some of the errors. Once the first “Alert” error has been flagged in the FERR or NERR (and matching SB frame data logged), the log registers for that error remain locked until either 1) all “Alert” error bits in the FERR and/or NERR are cleared, or 2) a power-up reset. Once the first Unimplemented Table 6-5. Other Errors Error Response Overtemp - Temp > TEMPHI and overtemp enabled If OVERTEMP error type enabled in EMASK Register 1. The OVERTEMP bit will be set in the FERR or NERR register as appropriate 2. Error/Alert Asserted bit set in FBD Status 0 register If TEMPHIENABLE set in TEMPSTAT register also 3. Shut down DDR channel: • Drive CKE low to the DRAMs and float the command, address, and data signals. CKE, ODT, and clock continue to be driven. The clocks to the DRAMS may be stopped after the CKE has been registered low 4. The FBD interface goes to electrical idle, with the receivers shut off to reduce power. 5. The core will continue to be clocked, and the AMB will respond to SMBus commands. This allows the host controller to determine the error condition Note: No recovery expected, just trying to prevent Si meltdown The AMB will remain in this state until the temperature is below TEMPHI and the OVERTEMP bit is reset via SMBus or a hardware reset. Else ignore error Note: A hardware reset will place the TEMPHIENABLE bit in its default state of disabled. Injected alert If INJCRC error type enabled in EMASK Register 1. No command executed 2. 120 bit Raw SB Frame captured in RECFBD Error Log Registers 3. Type of error logged in FERR/NERR registers 4. Error/Alert Asserted bit set in FBD Status 0 register 5. Ignore future commands except Soft Channel Reset until Soft Channel Reset or Link Reset Received 6. Alert Frame sent continuously starting with NB frame in which returned data pattern would be sent if aborted command had been a config read. Alert patterns continue until Soft Channel Reset or Link Fast Reset received. Else ignore error NOTE: this basically the same as a CRC error except that CRC is not actually corrupted Injected error If INJERR error type enabled in EMASK Register 1. Type of error logged in FERR/NERR registers 2. Error/Alert Asserted bit set in FBD Status 0 register Else ignore error No REFCLK Reset should not be released if no REFCLK present.PLL will not achieve lock, the AMB will not come out of reset. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |