24 / 92 page ![]() PAC1721 DS-20007088A-page 24 2026 Microchip Technology Inc. and its subsidiaries GPIO Triggered Single-shot Awake mode activates when the GPIO pin is pulled and held low for longer than 250 µs. This triggers the single-shot sample. I2C Triggered Single-shot mode is also available. It is used with a Refresh (any) command. Accumulator and accumulator count operate the same as for continuous conversion, summing every single-shot power calcula- tion and incrementing the accumulator count. The conversion cycle starts when the GPIO edge is sent or when a Refresh (any) command is issued. To enter GPIO Triggered Single-shot Awake mode from the Sleep state, set the following bits in the CONTROL register: •A0 → SAMPLE_MODE[3:0] = 1100b •A1 → SAMPLE_MODE[3:0] = 1101b 4.10 Alert Functionality If enabled, the Alert functionality notifies when: • A conversion cycle completes • The accumulator or accumulator count overflows • An electrical parameter exceeds the set limit • The rolling average of the most recent VBUS or VSENSE samples changes by more than expected Depending on the configuration, alerts trigger either the A0 pin or the A1 pin to be pulled low and latched low. The only exception is the Conversion Complete alert, when a 5 µs pulse of the ALERT pin occurs. Alerts are set at the end of conversion cycles. 4.10.1 ALERT PIN ASSIGNMENTS Before assigning any alerts, pin A0, pin A1 or both must be set to function as ALERT pins by programming the CONTROL register.: •A0 → SLOW_ALERT0[1:0] = 00b •A1 → GPIO_ALERT1[1:0] = 00b After configuring pin A0/A1 to function as ALERT pin, assign alerts to the pin using the SLOW_ALERT0 register for A0 and the GPIO_ALERT1 register for A1. For details, see Register 6-26 and Register 6-27. When an active alert triggers, except the Conversion Complete alert, PAC1721 sets the ANY_ALERT bit in the SMBUS_SETTINGS register to 1b. Monitor this bit over I2C, SMBus or on pin A0/A1 to determine if an alert was triggered. Clearing the alert that set the bit also clears the ANY_ALERT bit. Note: The SMBUS_SETTINGS register updates without requiring a Refresh (any) command. For more details, see Register 6-19. 4.10.2 CONVERSION COMPLETE ALERT When the Conversion Complete (CC) alert is enabled, the assigned ALERT pin is pulled and held low for 5 µs after each completed conversion cycle. To enable the Conversion Complete alert function on the ALERT pin, follow the next steps: 1. Program pin A0/A1 as ALERT pin(s) in the CONTROL register: ◦ A0 → SLOW_ALERT0[1:0] = 00b ◦ A1 → GPIO_ALERT1[1:0] = 00b 2. Enable the Conversion Complete alert: ALERT_ENABLE register: ALERT_CC = 1b 3. Assign the alert to the A0/A1 pin: ◦ If A0 is set as ALERT pin → SLOW_ALERT0 register: ALERT_CC0 = 1b ◦ If A1 is set as ALERT pin → GPIO_ALERT1 register: ALERT_CC1 = 1b Use the CC alert to read data continuously as soon as each conversion cycle is complete. For more details, see Register 6-26 and Register 6-27. Note 1: Jitter caused by the low power clocking scheme can be present when viewing the Conversion Complete alert. This does not impact the conversion cycle. 2: The Conversion Complete alert does not impact the ALERT_STATUS register. For more details, see Register 6-18. 4.10.3 ALERT FUNCTIONALITY – VOLTAGE, CURRENT AND POWER The Alert functionality enables the detection of voltage and current events that equal or exceed programmable limits, for one or more samples. To monitor alert status, set pin A0/A1 to correspond to a single specific alert or to multiple alerts by programming the corresponding bits in the SLOW_ALERT0 register for pin A0 and the GPIO_ALERT1 register for pin A1. For more details, see Register 6-26 and Register 6-27. Alert status can also be monitored over SMBus or I2C by reading the ALERT_STATUS register. For more details, see Register 6-18. Alerts can be triggered by various events: •VBUS overvoltage or undervoltage •VSENSE overcurrent or undercurrent • Fast rising or falling voltage or current • Overpower warning or overpower critical • Conversion cycle complete • Accumulator or accumulator count hitting a limit for fullness or overflow Note: The Slow function is disabled if the Alert function is programmed on the same pin. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |