41 / 166 page ![]() Datasheet 41 of 166 002-12337 Rev. *Y 2022-01-18 256Mb/512Mb/1Gb SEMPER™ Flash HYPERBUS™ interface, 1.8V/3.0V Features Figure 29 Password protection scheme flowchart Password protection notes • The Password Program Command is only capable of programming 0’s. • The password is all 1’s when shipped from CYPRESS™. It is located in its own memory space and is accessible through the use of the Password Program and Password Read commands. • All 64-bit password combinations are valid as a password. • Once the password is programmed and verified, the Password Protection Mode Locking bit must be programmed (to ‘0’) to prevent reading the password. • The Password Protection Mode Lock bit, once programmed (to 0), prevents reading the 64-bit password on the data bus and further password programming. All further program and read commands to the password region are disabled and these commands are ignored. In Legacy (x1) SPI, attempted programming of a protected Password will set the Program Status bit. In HYPERBUS™, attempted programming of a protected Password will set the Sector Lock Status bit and the Program Status bit. If a further programming operation is attempted on either the Password or the Password Protection Mode Lock bit the operation will be aborted and the failure will be indicated in the Status Register. There is no means to verify what the password is after the Password Protection Mode Lock bit is programmed. Password verification is only allowed before selecting the Password Protection mode. • The Password Mode Lock bit is not erasable. • The device requires tPSWD for setting the PPB Lock bit after the valid 64-bit password is given to the device. • The Password Unlock command is used to unlock the password. If the supplied password does not match the hidden internal password, the device gets locked out and does not accept any further instructions. Either a hardware reset or a CS# Signaling Reset or a power cycle are required to bring the device back to standby mode to try reentering the password again. • If the password is lost after setting the Password Mode Lock bit, there is no way to clear the PPB Lock bit. Power up Hardware Reset ASPPWD = 0 Password Protection Yes x PPBLock Bit = 0 x ASP Register Bits = Program Protected x PPB Bits = Erase/Program Protected PWD = Unlock x PPBLock Bit = 1 x ASP Register Bits = Program Protected x PPB Bits = Erase/Program UnProtected Yes Fail No Default Protection x PPBLock Bit = 1 x ASP Register Bits = Program UnProtected x PPB Bits = Erase/Program UnProtected |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |